Application:
The Controller is designed to manage the recirculation with anti-freezing liquid and the operation of the electrical heating elements of the water tank in solar systems with thermosiphone circulation.
- Equipped with two temperature sensors Pt1000 (-50° up to +200°C)
- Two independent relay outputs.
- Equipped with a Liquid Crystal Display, showing the assigned and present temperature levels.
- Regulate the temperature in the range between ( -30 °C) – (+120 °C).
- Hysteresis range of 1° to 40°C
- Weekly programmer
- Precision of the regulation +/-1°C.
- Warranty period of 24 months.
As an equivalent can be used TR-6.2.1